Edit this page Backlinks Add to book Export to PDF Book Creator Add this page to your book Book Creator Remove this page from your book Manage book (0 page(s)) Help PLC Settings Settings for S7-1200 / S7-1500 The optimized block access needs to be deactivated in the data block attributes for access to the S7-1200 and S7-1500. Additionally, in the S7-1500 the PUT / GET access must be enabled in the communication settings. You can see how this works here (snapshot from TIA Portal): Settings for LOGO! 1. Use the LOGO!Soft Comfort to set the IP address of the LOGO! PLC: 2. Configure the LOGO! PLC in such way that connections from an HMI device are accepted. To do so, go to “Tools- > Ethernet Connections” and then add a new connection. 3. Double-click on the newly created connection to access the properties. Select: Server Connection Local TSAP: 02:00 - 02:00 decentralized TSAP accept all connections. You can access DB1, inputs, outputs, flags, counters and timers with an IP-S7-LINK. Now via “Tools- > VM parameter map” set the variables that are to be transferred to the DB1. Pictures from Siemens Support Portal